4/2 way isolator valve, type Z4WE6.. .L3X

Function and configurationType Z4WE6 Isolator valves are solenoid operated directional spool valves. They control the flow connection and isolating of flow.Essentially the directional control valves c...

Product Detail

Function and configuration

Type Z4WE6 Isolator valves are solenoid operated directional spool valves. They control the flow connection and isolating of flow.

Essentially the directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and two return springs (4).

In the de-energized condition the control spool (3) is held in the neutral or initial position by means of return springs (4) (except for pulse valves). The control spool (3) is actuated via wet pin solenoids (2).

To ensure satisfactory operation care should be taken that the solenoid pressure chamber is filled with oil.

The force of the solenoids (2) acts via the push rod (5) on the control spool (3), control spool (3) is pushed from its neutral position to the required position. Then port A1, A2, B1 and B2 can be either connected or disconnected. P and T always flow freely.

When solenoid (2) is de-energised, the control spool (3) is returned to its neutral position by means of the return springs (4).

An optional hand override allows movement of the control spool without energizing the solenoid.

Ordering code

Symbols (① = valve side, ② = sub-plate side)

Technical data

Fixing positionOptional
Environment temperature range ℃-30 to +50 (NBR seals)
-20 to +50(FKM seals)
WeightSingle solenoid kg1.5
Double solenoids kg2.0
Max.operating
pressure
Port A,B,P bar315
Port T bar210 (DC), 160 (AC)
Max.flow L/min40
FluidMineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range ℃-30 to +80 (NBR seal)
-20 to +80 (FKM seal)
Viscosity range m㎡/s2.8 to 500
Degree of contaminationMaximum permissible degree of fluid contamination:
Class 9. NAS 1638 or 20/18/15, ISO4406

Electrical data

Type of voltageDCAC 50/60Hz
Usable voltage V12,24,96,110,205,220110,220,230
Voltage tolerance (nominal voltage) %+10~-15
Power consumption (DC) W30-
Holding power (AC) VA-50
Switch-on power (AC) VA-220
DutyContinuous
Switched timeON ms20 to 4510 to 20
Accord with ISO 6403OFF ms10 to 2515 to 40
Switched frequency times/hto 15000to 7200
Preventive grade according to DIN 40050IP65

Caution: with electrical connections the protective conductor(PE ⏚) must be connected according to the relevant regulations.

Characteristic curves (Measured at ϑₒᵢₗ = 40°C ± 5°C, using HLPE)

A2 to A1A1 to A2B2 to B1B1 to B2A2 to B2B2 to A2T2 to T2P2 to P1
D2441243277
E513113--77
E5322225277
E632553--77
E6844654577
E13714325677

Performance limit

Unit dimensions

Valve with DC solenoid

Unit dimensions

Valve with AC solenoid