4/3, 4/2 and 3/2 directional valve with wet-pin AC or DC solenoid, type WE6...L6X

Function and configurationsType WE valves are solenoid operated directional spool valves. They control the start, stop and direction of flow.The directional control valves consist of housing (1), one ...

Product Detail

Function and configurations

Type WE valves are solenoid operated directional spool valves. They control the start, stop and direction of flow.

The directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one or two return springs (4).

In the de-energized condition the control spool (3) is held in the neutral or initial position by means of return springs (4) (except for impulse spools).

The control spool (3) is actuated via wet pin solenoids (2).

To ensure proper operation, care must be taken that the pressure chamber of the solenoid is filled with oil.

The control spool(3) is moved to the expected position by solenoid(2) and pushing rod(5). This gives free-flow from P to A and B to T or P to B and A to T.

When solenoid (2) is de-energized, the control spool (3) is returned to its initial position by means of the return springs (4).

The solenoids may also control the control spool (3) by an optional override button(6) under the de-energized condition.

Type 4WE 6.. L6X/O...

(only for symbols A, C and D)

This version refers to directional valves with two spool positions and two solenoids without detent.

In the de-energized condition, there is no defined spool position.

Type 4WE 6.. L6X/OF...

(impulse spool, only for symbols A, C and D)

This version refers to directional valves with two spool positions, two solenoids and a detent. Due to this, both spool positions are positively held, and a permanent energization of the solenoid is not required.

Throttle insert (type 4WE 6..L6X/.../B..)

The use of throttle inserts is required, due to prevailing operating conditions, flows can occur during switching processes that exceed the performance limit of the valve. They are inserted in the P-channel of the directional valve.

Ordering code

Symbols

Characteristic curves (Measured at ϑoil = 40°C ± 5°C, using HLPM46)

7 Symbol "R" in switched positions B → A

8 Symbol "G" and "T" in neutral position P → T

9 Symbol "H" in neutral position P → T

Spool symbolFlow direction
PtoAP to B A to T B to T
A,B33--
C1131
D,Y5533
E3311
F1311
T101099
H2422
J,Q1121
L3349
M2433
P3111
R554-
V1211
W1122
U3394
G6699

Technical data

Fixing positionOptional
Environment temperature range ℃-30 to+50 (NBR seal)
-20 to+50 (FKM seal)
WeightSingle solenoid kg1.5
Double solenoids kg2.0
Max.operating pressurePort A,B,P bar350
Port T bar210 (DC),160 (AC), when the operating pressure exceed the permission value, port T must be used as drain port for spool symbol A and B
Max.flow-rate L/min80(DC),60(AC)
Flow cross section m㎡
(switching neutral position) m㎡
for symbol Q 6% of nominal cross section
for symbol W 3% of nominal cross section
FluidMineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range ℃-30 to+80 (NBR seal)
-20 to+80 (FKM seal)
Viscosity range m㎡/s2.8 to 500
Degree of contaminationMaximum permissible degree of fluid contamination:
Class 9. NAS 1638 or 20/18/15,ISO4406

Electric data

Type of voltageDCAC
Usable voltage V12,24,28,48,96,110,205,220110,127,220
Permissible voltage (deviation) %Standard solenoid: +10~-15
Large-scope solenoid: +20~-30
Power consumption WStandard solenoid: 30 Large-scope solenoid: 32
Holding power VA-50
Making capacity VA-220
DutyContinuous working
Switching time to ISO 6403ON ms25 to 4510 to 20
OFF ms10 to 2515 to 40
Switched frequency times/hto 15000to 7200
Type of protection to DIN 40050IP65(Z4, Z5L plug), IP67 (K7 Deutsch)
Max. coils temperature ℃+150+180

Caution: When connecting wires, properly connect the PE conductor (PE ⏚).

(For other type voltage please consult us.)

Performance limits (Measured at ϑoil = 40°C ± 5°C, using HLPM46)

The specified switching performance limits are valid with two directions of flow (e.g. from P to A and simultaneous return flow from B to T).

Due to the flow forces acting within the valve, the permissible switching performance limit can be significantly lower with only one direction of flow (e.g. from P to A, with port B being closed)!

The switching performance limit was determined with the solenoid at operating temperature, at 15 % under-voltage and without tank pre-loading.

Solenoid DCSolenoid AC-50HzSolenoid AC-60Hz
CurveSpool symbolCurveSpool symbolCurveSpool symbol
1A,B1)11A,B1)19A,B 1)
2V12V20V
3A,B13A, B21A,B
4F,P14F,P22F,P
5J15G,T23G,T
6G,H,T16H24J,L,U
7A/O,A/OF,L,U17A/O, A/OF,C/O,25A/O,A/OF, Q,W
8C,D,YC/OF, D/O, D/OF26C,D,Y
9ME,J,L,M27H
10E, C/O,C/OF
R2),(
Q,R2,,U,W28C/O, C/OF, D/O
D/O, D/OF, Q, W18C,D,YD/OF,M,R,E,R2)

Notes: ¹) With manual override; ²) Return flow from actuator to tank.

Solenoid DC
CurveSolenoid voltage(V)
1 to 1012,24,48,96,205

Solenoid AC
CurveSolenoid voltage
11 to 18W110110V,50Hz
W127127V,50Hz
W230230V,50Hz

Performance limits (Measured at ϑoil = 40°C ± 5°C, using HLP46)

Solenoid AC
CurveSolenoid voltage
11 to 18W110110V,50Hz
W127127V,50Hz
W230230V,50Hz

Solenoid DC
CurveSolenoid voltage
1 to 10 1)110,180
CurveSpool symbolCurveSpool symb olCurveSpool symbol
1A,B6T101)E,R,C/O,C/OF, D/O, D/OF, Q, W
2V7H
102)R,C/O,C/OF,D/O,D/OF, Q,W
3F,P8C,D
4J,L,U9M11A/O,A/OF
5G12E
Solenoid AC
CurveSolenoid voltage
1 to 12, see102)220

Unit dimensions

Valve with DC or rectification AC solenoid

Unit dimensions

Valve with AC solenoid