Function and configurationValve type Z2FS is a double throttle/check valve with sandwich plate structure.It is used to control the flow by changing the throttling. In the opposite direction, fluid flo...
Product Detail
Function and configuration
Valve type Z2FS is a double throttle/check valve with sandwich plate structure.
It is used to control the flow by changing the throttling. In the opposite direction, fluid flows freely through the check valve. For Z2FS10, depending on the installation position, the throttling effect may be arranged as a meter-in or a meter-out control. While for Z2FS16 and 22, depending on the model (S or S2) throttling may take place in either meter-in or meter-out, and at the same time the two operating oil chambers are connected.

Symbols

Ordering code

Technical data
| Installation position | Optional | |||
| Flow direction | One direction throttle, return through the check valve by another direction | |||
| Fluid | Mineral oil suitable for NBR and FKM seal, Phosphate ester for FKM seal | |||
| Fluid temperature range ℃ | -20 to+80 | |||
| Degree of contamination | Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406 | |||
| Viscosity range m㎡/s | 10 to 800 | |||
| Max.operating pressure bar | to 350 | |||
| Nominal size | 6 | 10 | 16 | 22 |
| Weight kg | 0.9 | 3.1 | 4.7 | 8 |
Characteristic curves (Measured at oil =40°C +5°C, using HLP46)

Unit dimensions:
. Outline dimension of double throttle/Check Valve Type Z2FS6

· Outline dimension of double throttle/Check Valve Type Z2FS10

Unit dimensions:
. Outline dimension of double throttle/Check Valve Type Z2FS16

. Outline dimension of double throttle/Check Valve Type Z2FS22