Pressure reducing valve, direct operated, type DR6DP...L5X

Function and configurationThe valve type DR6DP is a 3-way direct operated pressure reducing valve with a pressure relief function on the secondary side, to insure the secondary pressure steady. It is ...

Product Detail

Function and configuration

The valve type DR6DP is a 3-way direct operated pressure reducing valve with a pressure relief function on the secondary side, to insure the secondary pressure steady. It is used to reduce the system pressure. The secondary pressure is set by the pressure adjustment element (4).

At static position, the valve is normally open and the pressure fluid flows unhindered from port P to port A. The pressure in port A acts at the spool(2) area opposite to the compression spring (3) via the control line (6). When the pressure in port A get the value setting at compression spring (3), the control spool (2) moves into the control position and keeps the setting pressure in port A constant. The internal control oil is taken from port A via the control line (6). If the pressure in port A still increases due to external forces on the actuator, the control spool (2) moves still further towards the compression spring (3).This causes a flow path to be opened via control land(8) on the control spool (2).Sufficient fluid then flows back to tank to prevent any further pressure rise.

Fluid in spring chamber always drained to tank externally via port T(Y).

For free return flow from port A to port P an optional check valve(5) can be fitted One pressure gauge connection(1) used for monitoring the secondary pressure at the valve.

Type DR6DP1-L5X/...Y

Symbols

Ordering code

Technical data

FluidMineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range ℃-30 to+80(NBR seal)
-20 to+80 (FKM seal)
Viscosity range m㎡/s10 to 800
Degree of contaminationMaximum permissible degree of fluid contamination:
Class 9. NAS 1638 or 20/18/15, ISO4406
Max.operating pressurePort P315
Max.secondary pressurePort A bar
PortT(Y)
25; 75; 150; 210; 315(without check valve)
Max.backing pressure16
Max.flow-rate L/min60
Weight kgApprox.1.6

Characteristic curves (Measured at oil =40°C +5°C, using HLP46)

Notes:

The curve characteristics remain in a certain pressure range, with a low setting pressure.

The characteristic curves for the pressure relief function are valid when the back pressure is zero !

1 P to A (min. pressure differential)

2 A to T (Y) (min. pressure differential)

3 Pressure differential only over the check valve

4 Pressure differential over the check valve and fully opened cross section

Unit dimensions