Pilot operated pressure reducing valve, type DR...L5X

Function and configurationsPressure control valves type DR series L5X are pilot operated pressure reducing valves. They are used to control secondary circuit in a system. They consist mainly of the ma...

Product Detail

Function and configurations

Pressure control valves type DR series L5X are pilot operated pressure reducing valves. They are used to control secondary circuit in a system. They consist mainly of the main valve (1) with main spool assembly (3) and pilot valve (2) with pressure adjustment element.

At static state, the valves are normally open, fluid flows free from port B to port A via the main spool (3). Pressure at port A acts on the underside of main spool(3) and its spring-loaded side via throttle orifice(4). Fluid also acts on the ball valve(6) of the pilot valve(2) via the channel (5). Meanwhile, pressure fluid flows via throttle orifice (7), control line (8),check valve (9) and throttle orifice (10) to the ball valve(6). Based on the setting value of the spring (11), control piston(13) keeps open, then fluid can flow free from port B to port A, until pressure at port A exceed the setting value of spring(11), and then ball valve (6) is opened. Control piston (13) moves to close position. When pressure at port A is balanced with setting value at spring, pressure reducing is achieved as expected. Control oil returns from spring chamber(14) to tank via channel (15).

A check valve(16) can be fitted optionally to give free return flow from line A to B.

Pressure gauge connection(17), used for monitoring the reduced pressure at the port A.

Symbols

Ordering code

Technical data

FluidMineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range ℃-30 to+80 (NBR seal)
-20 to+80 (FKM seal)
Viscosity range m㎡/s10 to 800
Degree of contaminationMaximum permissible degree of fluid contamination:
Class 9. NAS 1638 or 20/18/15,ISO4406
Max.operating pressurePort B bar350
Operating pressure rangePort A bar10 to 350
Max.backing pressurePort Y bar350 (only for without check valve);
315 (with check valve)
Adjustable pressureMax. bar50;100;200;315;350
Min. barRelated with flow-rate (refer to the curves)
SizeDR10DR15DR20DR25DR30
Max.flow-rateSub-plate
L/min
mounting
150-300-400
Threaded
L/min
connection
150300300400400
Fixing positionOptional
SizeDR10DR15DR20DR25DR30
WeightSub-plate
mounting
DR kgApprox.3.6-Approx.5.3-Approx.8.2
Threaded
connection
DR...G kgApprox.5.3Approx.5.5Approx.5.1Approx.5.0Approx.5.0
DRC kgApprox.1.2
DRC30 kgApprox.1.5

(Measured at oil =40°C +5°C,using HLP46) Characteristic curves

Unit dimensions

Sub-plate mounting

TypeB1B2B3B4B5O-ring (PortA,B)O-ring (PortX,) Y)D
DR10855066.758.87.917.12x2.629.25x1.7813
DR2010259.579.4736.428.17x3.539.25x1.7822
DR301207696.892.83.834.52x3.539.25x1.7830
TypeL1L2L3L4L5L6L7L8L9L10H1H2H3
DR109635.53342.921.5-7.221.531.835.81129228
DR2011637.535.460.339.7-11.120.644.549.212210238
DR301453329.884.259.542.116.724.662.767.513011046

Unit dimensions

Threaded connections

Outline and installation dimension of Series 30 threaded connection valve:

TypeB1D3H1H2H3H4L1L2L3D1D2T1
DR10G6392712510628511.562G1/2;M22x1.53414
DR15GG3/4;M27x24216
DR20G57G1;M33x24718
DR25G70114213813641001472G1 1/4;M42x25820
DR30GG1 1/2;M48x26522

Unit dimensions

(DRC30) pilot valve with or (DRC30) without main spool assembly