Function and configurationDZ10DP sequence valve is direct-acting valve. It is for sequence switching related with secondary loop and pressure. Set sequence pressure through adjusting elements (1).Comp...
Product Detail
Function and configuration
DZ10DP sequence valve is direct-acting valve. It is for sequence switching related with secondary loop and pressure. Set sequence pressure through adjusting elements (1).
Compression spring (2) holds valve element (3) in initial position and the valve is closed. Pressure of Port A enters the valve element end through control route (4), of which the produced force acting on the valve element (3) on the opposite side of spring (2).
When the pressure reaches the set valve of spring (2), valve element (3) is pushed to connect port A and B; systems connected with oil port B is connected in sequence while the pressure of port A will not drop; control signal is acquired from port A via control route (4) or acquired from the outside via port X.
According to the valve purpose, leaked oil can return from the outside of port Y or the inside of port B.
Type: DZ10DP1-L4X/...Y

Symbols

Ordering code

Technical data
| Fluid | Mineral oil suitable for NBR and FKM seal | |
| Phosphate ester for FKM seal | ||
| Fluid temperature range ℃ | -30 to +80 (NBR seal) | |
| -20 to +80 (FKM seal) | ||
| Viscosity range m㎡/S | 10 to 800 | |
| Degree of contamination | Maximum permissible degree of fluid contamination: Class 9.NAS 1638 or 20/18/15, ISO4406 | |
| Max. operation pressure | oil port P,A, B( X) bar | 210 |
| Oil port T(Y) bar | 160 | |
| Max sequence pressure set bar (adjustable) with port B | 25;75;150;210 | |
| Max flow L/min | 80 | |
| Weight kg | About 3 | |
Characteristic curves (Measured at oil =40°C +5°C, using HLP46)

Unit dimensions