4/3, 4/2 and 3/2 directional valve with mechanical, manual operation, types WMR(U)10...L3X

FunctionDirectional valves, type WMR/U10.. are mechanical directional spool valves with roller/plunger. There are 2 position 3 way, 2 position 4 way and 3 position 4 way valves with many versions of s...

Product Detail

Function

Directional valves, type WMR/U10.. are mechanical directional spool valves with roller/plunger. There are 2 position 3 way, 2 position 4 way and 3 position 4 way valves with many versions of spool symbols, and the roller/plunger can be rotated by 90°.

The valves consist basically of the housing (1), roller/plunger (2), spool (3), return springs (4), and pushing rod (5). In the unoperated condition, the spool (3) is held in the initial position by the return spring, while in operated condition, the spool (3) is pushed to the expected position by roller/plunger (2) conquering the return springs (4).

Cartridge throttle

The use of a throttle insert is required, when, due to given operating conditions, flows can occur during the switching processes that exceed the performance limit of the valve.

These throttles are to be inserted into the P-channel of the directional valve.

Ordering code

Symbols

Technical data

Fluid temperature range ℃-30 to +80 (NBR seal)
-20 to+80 (FKM seal)
Max.operating pressurePort A,B,P bar315
Port T bar60
Max.flow-rate L/min120
Flow cross section (switching neutral position)TypeV m㎡For symbol V11(A/B to T) 10.3(Pt o A/B)
Type W m㎡For symbol W 2.5(A/B to T)
Type Q m㎡For symbol Q 5.5(A/B to T)
FluidMineral oil, Phosphate ester
Viscosity range m㎡/s2.8 to 500
Degree of contaminationMaximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406
Weight kg4

Operating limitation

Because of the adhesive effect, the switching function of the valves depends on the filtration. In order to achieve the specified admissible flow values, we recommend full flow filtration with 25 µm. The flow forces acting within the valves also affect the flow performance. With 4 way valves the specified flow data thus apply to normal operation with 2 volume flow directions (e.g. from P to A and at the same time return flow from B to T) (see table).

If only one flow direction is available, in critical cases, the admissible flow can be significantly smaller (e.g. when using a 4 way valve as 3 way valve, due to blocked connection A or B).

Characteristic curves (Measured at θₒᵢₗ=40℃±5℃, using HL P46)

8 Symbols "G" and "T" in mid position (P → T)

8 Symbol "R" in position (A → B)

Spool symbolFlow direction
P to A P to B A to T B to T
A43--
B34--
C3344
D3355
E2244
F1234
G,T4477
H1155
J2233
L3324
M1144
P3155
Q2222
R343-
U3352
V2233
W3333
Y4466