Function and configurationsThe type WMM valves are hand lever operation directional spool valves. They control the start, stop and direction of a flow.The directional valves basically comprise of a ho...
Product Detail
Function and configurations
The type WMM valves are hand lever operation directional spool valves. They control the start, stop and direction of a flow.
The directional valves basically comprise of a housing (1), hand lever (2), control spool (3), as well as one or two return springs (4).
In the unoperated condition the control spool (3) is held in the neutral or its initial position by the return springs (4). The control spool (3) is actuated by the hand lever (2) via a joint and a pin. The spool is thereby moved out of its initial position into switched position.
After the hand lever(2) has been returned to the zero switched position , the spool (3) is returned to the neutral position via the return springs (4).
4WMM.../F... (With the detent)
The directional valves with one detect , 2 or 3 switched position , can be orientated at any switched position.

Ordering code

Technical data
| Nominal size | 16 | 25 | 32 |
| Weight kg | Approx.8 | Approx.12.2 | Approx.49 |
| Actuation force-with spring retrn N | Approx.75 | Approx.105 | Approx.170 |
| -with detent N | Approx.75 | Approx.105 | Approx.170 |
| Actuation angle about the neutral postion 。 | 2x26° | 2x32° | 2x30° |
| Max.operating pressure port A,B,P bar | 315 | ||
| Port T bar | 250 | ||
| Fluid | Mineral oil suitable for NBR and FKM seal | ||
| Phosphate ester for FKM seal | |||
| Fluid temperature range ℃ | -30 to +80 (NBR seal) | ||
| -20 to +80 (FKM seal) | |||
| Viscosity range m㎡/s | 2.8 to 380 | ||
| Degree of contamination | Maximum permissible degree of fluid contamination: Class 9.NAS 1638 or 20/18/15, ISO4406 | ||
Symbols

Three-position can derive two-position(*A/*B)
Return spring and with detent

Notes:
For size 16, the port L should be used as drain port (X, Y are not used),
while for size 25 and 32, the port Y is used as drain port (X, L are not used).
Characteristic curves (Measured at θₒᵢₗ=40℃±5℃, using HL oil)

Characteristic curves (Measured at θₒᵢₗ=40℃±5℃, using HL oil)
The switching performance of the valves depends on the filtration. To achieve the specified admissible flow values, we recommend full flow filtration with 25 μm. The flow forces acting within the valves also affect the flow performance. With 4 way valves the specified flow data thus apply to normal operation with 2 volume flow directions (e.g. from P to A and at the same time return flow from B to T) (see table).
If only one flow direction is available, in certain cases, the admissible flow can be significantly smaller (e.g. when using a 4 way valve as 3 way valve, due to blocked connection A or B).
Nominal size 16
| Allowing flow qv L/min, 2-position valve | Allowing flow qv L/min, 3-position valve | ||||||||||
| Symbol | Operating pressure P bar | Symbol | Operating pressure P bar | ||||||||
| 70 | 140 | 210 | 280 | 315 | 70 | 140 | 210 | 280 | 315 | ||
| Return spring | Return spring | ||||||||||
| C | 300 | 300 | 300 | 260 | 220 | E,H,J,L,M,Q,R,U,W | 300 | 300 | 300 | 300 | 300 |
| D | 300 | 300 | 210 | 190 | 160 | F,P | 300 | 300 | 210 | 190 | 170 |
| K | 300 | 300 | 200 | 150 | 130 | G,S,T | 300 | 300 | 220 | 210 | 180 |
| Z | 300 | 240 | 190 | 170 | 150 | V | 300 | 260 | 200 | 180 | 170 |
| With detent | With detent | ||||||||||
| C,D,K,Z | 300 | 300 | 300 | 300 | 300 | E,H,J,L,M,Q,R,U,W | 300 | 300 | 300 | 300 | 300 |
| F,P | 300 | 300 | 280 | 230 | 230 | ||||||
| G,S,T | 300 | 300 | 230 | 230 | 230 | ||||||
| V | 300 | 300 | 250 | 230 | 230 | ||||||
Nominal size 25
| Allowing flow qv L/min, 2-position valve | Allowing flow qv L/min, 3-position valve | |||||||||||
| Symbol | Operating pressure P bar | Symbol | Operating pressure P bar | |||||||||
| 70 | 140 | 210 | 280 | 315 | 70 | 140 | 210 | 280 | 315 | |||
| Return spring | Return spring | |||||||||||
| C | 450 | 300 | 250 | 200 | 180 | E,J,L,M,Q,R,U,W | 450 | 450 | 450 | 450 | 450 | |
| D | 350 | 300 | 275 | 250 | 200 | F | 450 | 250 | 200 | 135 | 110 | |
| K | 200 | 150 | 140 | 130 | 120 | G,T | 450 | 330 | 290 | 230 | 180 | |
| Z | 300 | 270 | 240 | 220 | 200 | H | 450 | 450 | 400 | 400 | 350 | |
| P | 450 | 310 | 240 | 215 | 150 | |||||||
| V | 450 | 310 | 280 | 270 | 200 | |||||||
| With detent | With detent | |||||||||||
| C,D,K,Z | 450 | 450 | 450 | 450 | 450 | E,F,G,H,J,L,M, P,Q,R,T,U,W | 450 | 450 | 450 | 450 | 450 | |
| V | 450 | 450 | 400 | 350 | 300 | |||||||
Nominal size 32
| 2-position and 3-position valves with spring return | |||||
| Flow L/min Spool symbol | When...(bar) | ||||
| 70 | 140 | 210 | 280 | 315 | |
| E,J,L,M,Q, R,V,U,W | 1100 | 1050 | 860 | 750 | 680 |
| F,G,H,S,T,C,D,K,Z | 650 | 450 | 370 | 320 | 280 |
| 2-position and 3 | -position valves wi | th detent | |||
| All symbols | 1100 | 1050 | 860 | 750 | 680 |
Unit dimensions: nominal size 16

Unit dimensions: nominal size 25

Unit dimensions: nominal size 32