Function and configurationThe 4WRPEH type high-response valve is a pilot-operated directional control valve with electrical position feedback and integrated electronics (OBE).The valves basically cons...
Product Detail
Function and configuration
The 4WRPEH type high-response valve is a pilot-operated directional control valve with electrical position feedback and integrated electronics (OBE).
The valves basically consists of the housing (1), spool (2), sleeve (3), control solenoid with position transducer (4) and so on.
The specified command value is compared with the actual position value in the integrated electronics (OBE). In the event of a control deviation, the stroke solenoid is activated, which adjusts the control spool against the spring due to the change in the magnetic force.
Lifting/control cross-section is proportionally regulated to the command value. In case of a command value presetting of 0V, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.
Switch-off behavior
With the electronics switched off, the valve moves immediately into the relevant safe basic position (fail-safe). The switch position P–B/A–T is passed through during this process, which can result in movements on the controlled component. This must be taken into account in system.
Type 4WRPEH6...-L2X/G24...

Ordering code

Symbols

Technical data
| General | |||||||
| Design | Spool valve, direct operated,with steel sleeve | ||||||
| Actuation | Proportional solenoid with position control, OBE | ||||||
| Connection type | Subplate mounting, porting pattern according to ISO 4401-03-02-0-05 | ||||||
| Installation position | Any | ||||||
| Ambient temperature range | ℃ | -20~+50 | |||||
| Weight | Kg | ~2.75 | |||||
| Maximum vibration resistance (test condition) | Max.25 g,space vibration test in all directions (24h) | ||||||
| Hydraulic (measured at p=100bar, with HLP46 at Ooil=4 | 0℃±5℃) 0 : | ||||||
| pressure fluid | Mineral oil (HL, HLP) to DIN 51 524 | ||||||
| Viscosity range | Recommended Maximum admissible | m㎡/s m㎡/s | 20···100 | ||||
| 10···800 | |||||||
| Hydraulic fluid temperature range | ℃ | -20 to+70 | |||||
| Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) | Class 18/16/13 | ||||||
| Rated flow (Δp = 35bar per edge) | L/min | 2 | 4 | 12 | 24 | 40 | |
| Maximum operating pressure | bar | Port A, B,P:315 | |||||
| Maximum operating pressure | bar | Port T:250 | |||||
| Leakage flow at 100 bar | Linear | cm3/min | <150 | <180 | <300 | <500 | <900 |
| Nonlinear | cm3/min | - | - | - | <300 | <450 | |
| Static/Dynamic | |||||||
| Hysteresis | % | ≤0.2 | |||||
| Actuating time for signal step 0...100% | ms | 10 | |||||
| Temperature drift | 1% atΔT=40℃ Zero shift <° | ||||||
| Zero compensation | Ex factory ±1% | ||||||
| Electric, control electronics integrated in the valve | ||
| Relative duty cycle | % | 100ED |
| Protection class according to EN 60529 | IP 65. | |
| Connection | Plug-in connector 6P+PE, DIN 43563 | |
| Supply voltage Terminal A Terminal B | 24VDCnom | |
| min.21VDC/max.40VDC | ||
| OV (ripple max.2) | ||
| Fuse protection, external | 2.5 | |
| Input,version "A1" Terminal D (UE) Terminal E | Differential amplifier, Ri=100 kΩ | |
| 0...±10V | ||
| OV | ||
| Input,version "F1" Terminal D(ID-E) Terminal E (ID-E) | Load, Rsh=200Ω | |
| 4...12...20mA | ||
| Current loop IDreturn | ||
| Test signal, version "A1" Terminal F (UTest) Terminal C | LVDT | |
| 0...±10V | ||
| Reference 0 V | ||
| Test signal, version "F1" Terminal F (IFc) Terminal C(IFc) | LVDT signal 4...(12)... 20 mA on external load 200...500 Ωmaximum | |
| 4...(12)...20mA(output) | ||
| Current loop lF-c return | ||
| Adjustment | calibrated before delivery, see characteristic curves | |
1)The cleanliness level of the component must be reached in the hydraulic system.
Effective filtering prevents failures and increases the service life of components.
Electrical connection

Technical data for the cable

Integrated electronics (OBE)

Integrated electronics (OBE)

Characteristic curves(measured at p =100bar, with HLP46,oil =40°C +5°C)

Characteristic curves: Pressure amplification (measured at p=100bar, with HLP46, oil=40°C +5°C)

Characteristic curves: Bode diagram (measured at p=100bar, with HLP46, oil =40°C +5°C)

Unit dimensions